Sentry 6140 Tip Flow Monitor
Boom Series Harness Connection
With each machine having a different possible switchbox conguration, it is impossible to specify the exact location to T-Tap
into the valve harness. However, the following guidelines may provide some assistance in completing the installation.
1. Identify boom section cable that runs from the Boom Switchbox to the boom valves.
2. Use a T-Tap (or similar product) to connect into the signal wire.
NOTE: In some cases, the Boom Series Harness wires can be connected directly to the switches inside the Switchbox
using the proper spade terminal.
3. Repeat this process for each individual boom section.
Figure 2: Boom Series Harness Connection
45-10142
Boom Sense Harness
RATE CONTROLLER
Ground
Wire
+Power
Wire
Boom Valve
Signal Wire
Boom Series Harness
Boom Wire
Wire Tap
A
Detail A