Sentry 6140 Tip Flow Monitor
TIP BALANCE
Balancing the tips is required for the system to compare and
monitor individual tips. The system will scan all the tips to get the
ow rate. The ow rate of each tip must be within the tip balance
percentage range of the average ow rate in order to balance
successfully. If any tip is outside this range, an error will be generated,
and the user will need to inspect the tip.
NOTE: In order to maintain system accuracy, balancing the tips is
required anytime a tip is changed.
The console will not be able to detect small flow changes
until a tip balancing is completed successfully.
Tip Balance Percentage is OEM specified. Default balance
is +/-15%.
Figure 23: Tip Balance
Balance
Status Box
showing tip error
Boom Status
Next Error
Home
To check if the tips are balanced:
1. Machine must be spraying at normal operation parameters.
2. Press BALANCE button
on the Home Screen.
3. Press BALANCE button
to start the balance check. The
on-screen boom sections will ow on and off during this
check.
4. If an error occurs, the Status Box and boom section will ash red.
The Status Box show the tip or tips that are at fault including their
percentage of error or N/C for “not connected”. Inspect the tip(s)
noted on the Status Box. The LED on the Tip Sensor Interface
(H or I) will also be illuminated corresponding to the tip or tips that
are at fault.
The NEXT ERROR button
is only enabled if more than one
error is found when balancing the tips.
5. After correcting the problem, press BALANCE button
to start
new balance check.
Figure 24: Tip Balance Process