Teejet Matrix Pro 840G BoomPilot Setup User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
11
98-05243-ENUS R2
Matrix
®
Pro
Overlap
Overlap determines the amount of overlap allowed when the each
boom section is turned on and off using Automatic Boom Section
Control. Default is 50%.
1. Press DOWN arrow to access the list of options.
2. Select:
►0%
►50%
►100%
Figure 1-23: Overlap
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
0%
50%
100%
100%
50%
0%
Delay On
Delay On functions as a “look ahead” for establishing the timing for the
boom section valves to switch on exactly when entering an area that
has not been applied. If the boom turns on too soon when entering a
non-applied area, decrease the Delay On setting. If the boom turns
on too late when entering a non-applied area, increase the Delay On
setting. Range is 0.0 - 10.0 seconds. Default is 1.00 second.
1. Press the KEYPAD icon .
2. Use the entry screen to establish the delay on time.
Figure 1-24: Delay On
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
Delay On Time (s)
1 2 3
Clear
4 5 6 <--
7 8 9
0 .
+/-
Delay Off
Delay Off functions as a “look ahead” for establishing the timing for
the boom section valves to switch off exactly when entering an area
that has been applied. If the boom turns off too soon when entering
an applied area, decrease the Delay Off setting. If the boom turns off
too late when entering an applied area, increase the Delay Off setting.
Range is 0.0 - 10.0 seconds. Default is 1.00 second.
1. Press the KEYPAD icon .
2. Use the entry screen to establish the delay off time.
Figure 1-25: Delay Off
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
Delay O Time (s)
1 2 3
Clear
4 5 6 <--
7 8 9
0 .
+/-
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments