58 CenterLine
Swath Manager 5 Operation
CenterLine
Software Version 2.00
Swath Manager 5 Auto Boom Engage:
• Rate Controller section switches must be OFF.
• Rate Controller section switches in the ON position override the Swath Manager 5.
• Rate Controller master switch must be in the ON position.
• Rate Controller master switch in the OFF position overrides the Swath Manager 5.
• Swath Manager 5 master switch and section switches must be in the ON position.
• Swath manager 5 auto boom switch must be set to engage.
Swath Manager 5 Auto Boom Disengage
• Both switches for a particular section (the one on the controller and the one on the
Swath Manager 5) must be off in order for that section to be off.
• Swath manager 5 auto boom switch must be set to Disengaged.
• Section Status is still passed to the Centerline when Auto Boom has been
disengaged.
Figure 62: Switch Settings to Engage Swath Manager 5
MASTER
54321
BOOM CONTROL
AUTO
BOOM
DISENGAGE
ENGAGE
Swath Manager 5
Automated Boom
Section Control
Auto
Man
P
RO
Hold 2 sec.
Press to DEFAULT
Hold to CLEAR
TeeJet VisiFlo color coding only. For other tips see manual.
P
AUTO
CAL
Tee et
J
®
MASTER
12 345
Master & Boom Sections ON
Auto Boom
Engaged
Boom Sections OFF
Master ON
Swath Manager 5
Rate Controller