16 LH A
GRO
SECONDARY FUNCTIONS; SLURRY SPREADER
APPLICATION RATE MONITORING
Flow metering is possible on slurry spreaders either by using a flowmeter
(electromagnetic) or by a RPM sensor fitted to a positive displacement pump
(exact volume per revolution).
By encoding an amount in kilos (with 2 decimals) per impulse as a flow figure the
following functions are available:
ENCODE:
XXXX is the known calibration figure in kg with
2 decimals. 5.00 kg is encoded as 500 The
application rate will be shown as m
3
/ha.
Key Function
SLURRY APPLICATION RATE
SLURRY CONSUMPTION PER MINUTE
TOTAL SLURRY CONSUMPTION
NOTE! It is a condition for correct operation of all three functions that the flow
sensor is calibrated.