Teejet IC18 NH3 JOB COMPUTER User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
31
98-05230 R0 US
ISOBUS Job Computer : IC18 NH3
OVERVIEWSETUPAPPENDIX GETTING STARTEDOPERATION
OEM
The OEM setup menu is password protected and the settings in this menu are directly related to the tted OEM
equipment. To obtain an access code, contact your local dealer or TeeJet Technologies Customer Service.
To access the OEM screens:
Figure 3-24: Machine to OEM
Figure 3-25: OEM Unlock
1. From the Main Setup Screen , select MACHINE.
2. Select OEM.
3. Select the Access Code Entry Box to the right of the
menu option.
4. Use the number pad or slide bar to enter the access
code.
5. Select the ACCEPT KEY to complete the unlock
process
6. Select from:
►Sensor presence – used to establish sensors for
Flow and Liquid Pressure
►Implement parameters – used to establish the
Sprayer Mode and Number of Sections
►Valve setup – used to establish the Regulation
Valve Type and Section Valve Behavior
►Tank setup – used to establish maximum and
minimum tank content
►Regulation details – used to adjust the control of
the regulation valve
►Clear total counters – used to delete the Total
Count system counter for Area, Volume and Time
back to the default settings
NOTE: Settings are NOT automatically saved when
selected. The ACCEPT KEY must be selected
to save the setting. Select the ESCAPE KEY
to escape without saving settings and return to the
previous menu. OEM
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 62 63

Comments to this Manuals

No comments