OVERVIEW SETUP APPENDIXGETTING STARTED OPERATION
Filling
Filling establishes the amount of material remaining in the tank and the density of that material.
NOTE: The size of the tank is established in the OEM menu. This is the number that will repopulate when the Full
Tank Key is pressed.
Figure 3-14: Filling
Actual Content
Actual Content displays the current volume of content in
the tank. The volume can be manually adjusted.
To adjust thevolume, use the number pad or slide
bar.
Density Factor
Density Factor establishes the weight per volume setting
based on the type of fertilizer being used.
To select the Density Factor, use the number pad or
slide bar.
The fertilizer’s ability to ow is affected by a number of
factors. These factors may vary with each batch and it
may change due to weather (humidity, etc.). In order to accommodate for this, the job computer uses a density
factor to compensate for the nature of the applied fertilizer.
Full Tank
Full Tank returns the Actual Content volume value to the maximum volume of the tank
To reset the Actual Content value, press the FULL TANK KEY .