A
PPLICATION CONTROL
, ENCODE &
CALIBRATION
LH 665 VRT O
PERATORS MANUAL
4.14 LH A
GRO
FAULTFINDING
Fault Cause Solution
No connection between the
LH 665 and the implement
controller.
Check the connection
between the LH 665 and the
implement controller.
The LH 665 is receiving no
DGPS signals.
See "No DGPS signal (D or
G not displayed)" on page
4.15.
The implement is outside the
field boundary.
If the implement is outside
the field boundary and the
"Target rate outside field"
setting is set to Zero the
application rate will be = 0.
See page 4.5
The application
rate on the
implement
controller =0:
The application rate from the
target file = 0.
Check that the application
rate for the area being
applied.
No connection between the
LH 665 and the implement
controller.
Check the connection
between the LH 665 and the
implement controller.
GPS speed is different than
actual forward speed
displayed on the implement
controller.
The accuracy of GPS speed
varies depending on the
quality of the DGPS receiver.
The forward speed sensor
on the implement controller
has not been calibrated
correctly.
Calibrate the forward speed
sensor fitted to the
implement controller.
The LH 665 did not count
area when the application
rate is 0.
The LH 665 only measures
area when the application
rate is greater than 0.
The working width (swath)
displayed on the LH 665 = 0.
If the implement controller is
working and the working
width is greater than 0,
check the connection
between the LH 665 and the
implement controller.
The area measured
in the LH 665 is
not the same as
the implement
controller:
The area override switch is
"down" on the front of the LH
665
The area override switch
must be "up" to measure
area.